<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-M5MG9RCD" height="0" width="0" style="display:none;visibility:hidden"></iframe>
Login
Contact

MGate MB3660 Series Modbus gateways

Model: MGate MB3660

Category: Smart Factory

Exhibitor:

MOXA INC.

Booth No: N204

0
Share :
Share :

Description
The MGate MB3660 (MB3660-8 and MB3660-16) gateways are redundant Modbus gateways that convert between the Modbus TCP and Modbus RTU/ASCII protocols. They can be accessed by up to 256 TCP master/client devices, or connect to 128 TCP slave/server devices. Routing through the serial ports can be controlled by IP address, TCP port number, or ID mapping. Serial-port routing by designated TCP port and IP address allows access for up to 4 TCP clients/masters, while routing by ID mapping (slave ID table) allows access for up to 256 TCP clients/masters. The MGate MB3660 isolation model provides 2-kV isolation protection suitable for power substation applications. The MGate MB3660 gateways are designed to easily integrate Modbus TCP and RTU/ASCII networks. The MGate MB3660 gateways offer features that make network integration easy, customizable, and compatible with almost any Modbus network.

For large-scale Modbus deployments, MGate MB3660 gateways can effectively connect a large number of Modbus nodes to the same network. The MB3660 Series can physically manage up to 248 serial slave nodes for 8-port models or 496 serial slave nodes for 16-port models (the Modbus standard only defines Modbus IDs from 1 to 247). Each RS-232/422/485 serial port can be configured individually for Modbus RTU or Modbus ASCII operation and for different baudrates, allowing both types of networks to be integrated with Modbus TCP through one Modbus gateway.

High Performance with Innovative Command Learning

The MGate MB3660 gateways support two communication modes: transparent mode and agent mode. For transparent mode, the gateway converts Modbus commands from Modbus TCP to Modbus RTU/ASCII, and vice versa, or from serial (master) to serial (slave). However, since only one Modbus protocol request-response action can be executed at any given time, each Modbus device has to wait its turn, resulting in poorer performance.

In order to provide better performance, the MGate MB3660 gateways are designed with an innovative Command Learning function, which can be activated with a single mouse click. Once activated, the gateway will learn and remember the Modbus commands it receives, and once a command has been learned, the gateway will act as though it were in agent mode, and actively send Modbus requests to the relevant Modbus devices. Since the data is saved in a different memory space that can be accessed by the SCADA system, the SCADA system can retrieve Modbus response data directly from the gateway’s memory, instead of waiting for the data to pass through the Modbus devices, dramatically increasing communication performance.

Auto-Device Routing for Easy Configuration

Moxa’s Auto-Device Routing function helps eliminate many of the problems and inconveniences encountered by engineers who need to configure large numbers of Modbus devices. A single mouse click is all that’s required to set up a slave ID routing table and configure Modbus gateways to automatically detect Modbus requests from a supervisory control and data acquisition (SCADA) system. By removing the need to manually create the slave ID routing table, the Auto-Device Routing function saves engineers significant time and reduces cost.

Modbus Gateway with Power and Ethernet Redundancy

For a complicated Modbus system, redundancy is extremely important. The MGate MB3660 Modbus gateways support redundancy for both the power input and Ethernet connection. The MGate MB3660 gateways come with dual AC or DC power inputs built in for power redundancy, and have dual Ethernet ports (with different IPs) for network redundancy. To accommodate different types of applications, the dual Ethernet ports can be configured in one of two ways:

Use the same IP for both Ethernet ports. In this case, the MGate MB3660 gateway will automatically switch to the backup LAN when the main LAN fails.

Use different IP addresses for each of the two Ethernet ports. In this case, Modbus clients/masters can use both Ethernet ports to communicate with Modbus RTU/ASCII slave devices at the same time.

Related Products
EDS-4000/G4000 Series managed Ethernet switches
AIG-301 Series IIoT gateways
Moxa Wi-Fi 部署服務
Moxa 工業網路 維運中心(iNOC)服務
SDS-3006 Series PoE smart Ethernet switches
AWK-3262A Series wireless AP/bridge/client
BXP-A101 Series x86 computer
NPort 6100-G2/6200-G2 Series secure terminal servers
EDF-G1002-BP Series LAN firewalls
You may also like
ORing_Industrial-grade 8-port managed TSN Ethernet switch (CC-Link IE TSN Testing)
3D NIR
AEM-DRB Multi-Circuit Power Meter (DIN rail)
Micro robot
Automatic Industrial Cordless Brushless Medium / Low Torque Battery Screwdrivers Series
Automated Conveyor System
Low Information Security Risk MES
Energy Management Solutions
AWS Cloud Data Logger
LED 三色溫天井燈 100W / 150W / 200W
Refrigeration Expert XP Plug-n-play monitoring and remote maintenance for small stores
Dyeing Machine Controller
IoTstar IoT Cloud Management Software
AMR/AGV
Embedded Vision
Safety Components
Motor Equipment Health Management System
AGV, RGV, MGV Dust And Oxygen-Free Oven
MITSUBISHI ELECTRIC ENGINEERING Co., Ltd._DA/AD signal converter
WAGO Electronic Circuit Breakers (ECBs)
Hygienic flow meter with IO-Link
NLC -customer made dispenser
(Cylinder type) Wireless Intelligent Vibration &amp; Temperature Sensor
Machine Automation Controller
Factory Energy Management System

Highest Rated Products

AMR Robot
AI Master
FOBA F0100-ir 超快雷射雕刻系統
Multi-Axis Robot
M20W MINI fiber laser marking and engraving machine
AGS-7 Robot Polishing Station
collaborative arm
ATM3 3D Air Aurora Machine
HALCON
COMPACT ARM CAW SERIES
Elastomer Couplings
Bellows Couplings
Disc Pack Couplings
Torque Limiters
Line Shaft Couplings
Customized Couplings
Gear Couplings
ATEX Couplings & Torque Limiters
Xsmart On-Line XRF
ROBOT
Electric Gripper Series
AI NVH
Unitree Go2/ B2
Insole Pressure Sensor
R+W Germany Precision Coupling & Torque Limiter
particle extractor
Automatic welding equipment kit
Wet Dust Collector
AI Machine Vision Cameras System
Collaborative Robot HC Series
Back